Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Adv ; 10(12): eadj9708, 2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38507488

RESUMEN

Textile sensors transform our everyday clothing into a means to track movement and biosignals in a completely unobtrusive way. One major hindrance to the adoption of "smart" clothing is the difficulty encountered with connections and space when scaling up the number of sensors. There is a lack of research addressing a key limitation in wearable electronics: Connections between rigid and textile elements are often unreliable, and they require interfacing sensors in a way incompatible with textile mass production methods. We introduce a prototype garment, compact readout circuit, and algorithm to measure localized strain along multiple regions of a fiber. We use a helical auxetic yarn sensor with tunable sensitivity along its length to selectively respond to strain signals. We demonstrate distributed sensing in clothing, monitoring arm joint angles from a single continuous fiber. Compared to optical motion capture, we achieve around five degrees error in reconstructing shoulder, elbow, and wrist joint angles.


Asunto(s)
Materiales Inteligentes , Textiles , Movimiento , Programas Informáticos , Algoritmos
2.
Adv Sci (Weinh) ; 10(22): e2206665, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37208801

RESUMEN

Mobile health technology and activity tracking with wearable sensors enable continuous unobtrusive monitoring of movement and biophysical parameters. Advancements in clothing-based wearable devices have employed textiles as transmission lines, communication hubs, and various sensing modalities; this area of research is moving towards complete integration of circuitry into textile components. A current limitation for motion tracking is the need for communication protocols demanding physical connection of textile with rigid devices, or vector network analyzers (VNA) with limited portability and lower sampling rates. Inductor-capacitor (LC) circuits are ideal candidates as textile sensors can be easily implemented with textile components and allow wireless communication. In this paper, the authors report a smart garment that can sense movement and wirelessly transmit data in real time. The garment features a passive LC sensor circuit constructed of electrified textile elements that sense strain and communicate through inductive coupling. A portable, lightweight reader (fReader) is developed for achieving a faster sampling rate than a downsized VNA to track body movement, and for wirelessly reading sensor information suitable for deployment with a smartphone. The smart garment-fReader system monitors human movement in real-time and exemplifies the potential of textile-based electronics moving forward.


Asunto(s)
Textiles , Dispositivos Electrónicos Vestibles , Humanos , Movimiento (Física) , Movimiento
3.
Small ; 19(24): e2301381, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36919263

RESUMEN

Given the ability to convert various ambient unused mechanical energies into useful electricity, triboelectric nanogenerators (TENGs) are gaining interest since their inception. Recently, ionogel-based TENGs (I-TENGs) have attracted increasing attention because of their excellent thermal stability and adjustable ionic conductivity. However, previous studies on ionogels mainly pursued the device performance or applications under harsh conditions, whereas few have investigated the structure-property relationships of components to performance. The results indicate that the ionogel formulation-composed of a crosslinking monomer with an ionic liquid-affects the conductivity of the ionogel by modulating the cross-link density. In addition, the ratio of cross-linker to ionic liquid is important to ensure the formation of efficient charge channels, yet increasing ionic liquid content delivers diminishing returns. The ionogels are then used in I-TENGs to harvest water droplet energy and the performance is correlated to the ionogels structure-property relationships. Improvement of the energy harvesting is further explored by the introduction of surface polymer brushes on I-TENGs via a facile and universal method, which enhances droplet sliding by means of ideal surface contact angle hysteresis and improves its anti-reflective properties by employing the I-TENG as a surface covering for solar cells.

4.
Adv Mater ; 35(10): e2209321, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36504252

RESUMEN

The development of flexible strain sensors over the past decade has focused on accessing high strain percentages and high sensitivity (i.e., gauge factors). Strain sensors that employ capacitance as the electrical signal to correlate to strain are typically restricted in sensitivity because of the Poisson effect. By employing auxetic structures, the limits of sensitivity for capacitive sensors have been exceeded, which has improved the competitiveness of this modality of sensing. In this work, the first employment of helical auxetic yarns as capacitive sensors is presented. It is found that the response of the helical auxetic yarn capacitive sensors (termed as HACS) is dependent on the two main fabrication variables-the ratio of diameters and the helical wrapping length. Depending on these variables, sensors that respond to strain with increasing or decreasing capacitance values can be obtained. A greater auxetic character results in larger sensitivities accessible at smaller strains-a characteristic that is not commonly found when accessing high gauge factors. In addition, the highest sensitivity for auxetic capacitive sensors reported thus far is obtained. A mechanism of sensor response that explains both the variable capacitance response and the high gauge factors obtained experimentally is proposed.

5.
Adv Sci (Weinh) ; 9(11): e2106008, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35187859

RESUMEN

Flexible triboelectric nanogenerators (TENGs) have attracted increasing interest since their advent in 2012. In comparison with other flexible electrodes, hydrogels possess transparency, stretchability, biocompatibility, and tunable ionic conductivity, which together provide great potential as current collectors in TENGs for wearable applications. The development of hydrogel-based TENGs (H-TENGs) is currently a burgeoning field but research efforts have lagged behind those of other common flexible TENGs. In order to spur research and development of this important area, a comprehensive review that summarizes recent advances and challenges of H-TENGs will be very useful to researchers and engineers in this emerging field. Herein, the advantages and types of hydrogels as soft ionic conductors in TENGs are presented, followed by detailed descriptions of the advanced functions, enhanced output performance, as well as flexible and wearable applications of H-TENGs. Finally, the challenges and prospects of H-TENGs are discussed.


Asunto(s)
Hidrogeles , Dispositivos Electrónicos Vestibles , Electrodos , Iones
6.
Sensors (Basel) ; 20(19)2020 Sep 29.
Artículo en Inglés | MEDLINE | ID: mdl-33003316

RESUMEN

Fatigue is a multifunctional and complex phenomenon that affects how individuals perform an activity. Fatigue during running causes changes in normal gait parameters and increases the risk of injury. To address this problem, wearable sensors have been proposed as an unobtrusive and portable system to measure changes in human movement as a result of fatigue. Recently, a category of wearable devices that has gained attention is flexible textile strain sensors because of their ability to be woven into garments to measure kinematics. This study uses flexible textile strain sensors to continuously monitor the kinematics during running and uses a machine learning approach to estimate the level of fatigue during running. Five female participants used the sensor-instrumented garment while running to a state of fatigue. In addition to the kinematic data from the flexible textile strain sensors, the perceived level of exertion was monitored for each participant as an indication of their actual fatigue level. A stacked random forest machine learning model was used to estimate the perceived exertion levels from the kinematic data. The machine learning algorithm obtained a root mean squared value of 0.06 and a coefficient of determination of 0.96 in participant-specific scenarios. This study highlights the potential of flexible textile strain sensors to objectively estimate the level of fatigue during running by detecting slight perturbations in lower extremity kinematics. Future iterations of this technology may lead to real-time biofeedback applications that could reduce the risk of running-related overuse injuries.


Asunto(s)
Fatiga/diagnóstico , Textiles , Dispositivos Electrónicos Vestibles , Fenómenos Biomecánicos , Femenino , Humanos , Aprendizaje Automático , Movimiento
7.
Sensors (Basel) ; 19(23)2019 Dec 03.
Artículo en Inglés | MEDLINE | ID: mdl-31816931

RESUMEN

Continuous kinematic monitoring of runners is crucial to inform runners of inappropriate running habits. Motion capture systems are the gold standard for gait analysis, but they are spatially limited to laboratories. Recently, wearable sensors have gained attention as an unobtrusive method to analyze performance metrics and the health conditions of runners. In this study, we developed a system capable of estimating joint angles in sagittal, frontal, and transverse planes during running. A prototype with fiber strain sensors was fabricated. The positions of the sensors on the pelvis were optimized using a genetic algorithm. A cohort of ten people completed 15 min of running at five different speeds for gait analysis by our prototype device. The joint angles were estimated by a deep convolutional neural network in inter- and intra-participant scenarios. In intra-participant tests, root mean square error (RMSE) and normalized root mean square error (NRMSE) of less than 2.2° and 5.3%, respectively, were obtained for hip, knee, and ankle joints in sagittal, frontal, and transverse planes. The RMSE and NRMSE in inter-participant tests were less than 6.4° and 10%, respectively, in the sagittal plane. The accuracy of this device and methodology could yield potential applications as a soft wearable device for gait monitoring of runners.


Asunto(s)
Monitoreo Ambulatorio/instrumentación , Redes Neurales de la Computación , Textiles , Dispositivos Electrónicos Vestibles , Adulto , Algoritmos , Articulación del Tobillo/patología , Fenómenos Biomecánicos , Vestuario , Diseño de Equipo , Marcha , Articulación de la Cadera/patología , Humanos , Articulación de la Rodilla/patología , Aprendizaje Automático , Masculino , Monitoreo Ambulatorio/métodos , Movimiento (Física) , Reproducibilidad de los Resultados , Adulto Joven
8.
Sensors (Basel) ; 19(19)2019 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-31623321

RESUMEN

Wearable electronics are recognized as a vital tool for gathering in situ kinematic information of human body movements. In this paper, we describe the production of a core-sheath fiber strain sensor from readily available materials in a one-step dip-coating process, and demonstrate the development of a smart sleeveless shirt for measuring the kinematic angles of the trunk relative to the pelvis in complicated three-dimensional movements. The sensor's piezoresistive properties and characteristics were studied with respect to the type of core material used. Sensor performance was optimized by straining above the intended working region to increase the consistency and accuracy of the piezoresistive sensor. The accuracy of the sensor when tracking random movements was tested using a rigorous 4-h random wave pattern to mimic what would be required for satisfactory use in prototype devices. By processing the raw signal with a machine learning algorithm, we were able to track a strain of random wave patterns to a normalized root mean square error of 1.6%, highlighting the consistency and reproducible behavior of the relatively simple sensor. Then, we evaluated the performance of these sensors in a prototype motion capture shirt, in a study with 12 participants performing a set of eight different types of uniaxial and multiaxial movements. A machine learning random forest regressor model estimated the trunk flexion, lateral bending, and rotation angles with errors of 4.26°, 3.53°, and 3.44° respectively. These results demonstrate the feasibility of using smart textiles for capturing complicated movements and a solution for the real-time monitoring of daily activities.


Asunto(s)
Monitoreo Fisiológico , Movimiento/fisiología , Dispositivos Electrónicos Vestibles , Fenómenos Biomecánicos , Humanos , Aprendizaje Automático , Movimiento (Física) , Rango del Movimiento Articular/fisiología , Textiles , Torso/fisiología
9.
Angew Chem Int Ed Engl ; 57(39): 12707-12710, 2018 09 24.
Artículo en Inglés | MEDLINE | ID: mdl-29996005

RESUMEN

There is currently an urgent need for the development of new antibacterial agents to combat the spread of antibiotic-resistant bacteria. We explored the synthesis and antibacterial activities of novel, sugar-functionalized phosphonium polymers. While these compounds exhibited antibacterial activity, we unexpectedly found that the control polymer poly(tris(hydroxypropyl)vinylbenzylphosphonium chloride) showed very high activity against both Gram-negative Escherichia coli and Gram-positive Staphylococcus aureus and very low haemolytic activity against red blood cells. These results challenge the conventional wisdom in the field that lipophilic alkyl substituents are required for high antibacterial activity and opens prospects for new classes of antibacterial polymers.


Asunto(s)
Antibacterianos/química , Polímeros/química , Azúcares/química , Antibacterianos/farmacología , Escherichia coli/efectos de los fármacos , Hemólisis/efectos de los fármacos , Interacciones Hidrofóbicas e Hidrofílicas , Pruebas de Sensibilidad Microbiana , Compuestos Organofosforados/química , Polímeros/síntesis química , Polímeros/farmacología , Staphylococcus aureus/efectos de los fármacos , Compuestos de Vinilo/química
10.
ACS Omega ; 2(6): 2593, 2017 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-31465017

RESUMEN

[This corrects the article DOI: 10.1021/acsomega.6b00193.].

11.
J Mater Chem B ; 4(28): 4872-4883, 2016 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-32263146

RESUMEN

The development of new approaches to antibacterial surfaces is of growing interest to combat the spread of harmful bacterial infections. Relative to polyammoniums, polyphosphoniums can exhibit enhanced chemical and thermal stability, but have not yet been widely explored for the preparation of antibacterial surfaces. In this work, polyphosphoniums of varying chain lengths were synthesized by reversible addition-fragmentation chain-transfer polymerization of 4-vinylbenzyl derivatives of triethyl, tributyl, and trioctylphosphonium. These polyphosphoniums were then incorporated into semi-interpenetrating networks (SIPNs) based on tetra(ethylene glycol) diacrylate (TEGDA) via a UV light-initiated curing process. Measurements of cure percentage, gel content, water contact angle, and surface charge density suggested that all polyphosphoniums were well integrated into the network with the exception of one formulation. The results also suggested that the triethylphosphonium system tended to undergo surface reversion. Even at relatively low loadings of 0.1 to 10 wt% of polyphosphonium, the surfaces exhibited high accessible surface charge. Antibacterial testing revealed high activity against S. aureus for the triethyl and tributylphosphonium SIPNs and lower activity for the trioctyl systems. On the other hand, antibacterial activity against E. coli increased with increasing alkyl chain length. This can likely be attributed to differences in the compositions of the membranes of Gram-positive versus Gram-negative bacteria. The results also indicated that while killed bacteria tended to adsorb to the surface of the triethylphosphonium system, the more hydrophobic surfaces were more effective at preventing bacterial adsorption.

12.
J Mater Chem B ; 3(8): 1474-1478, 2015 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-32262419

RESUMEN

Described here is a simple and versatile approach for the preparation of antibacterial phosphonium-based coatings through the curing of a polymerizable tributylphosphonium monomer using UV light. The resulting surfaces resist bacterial growth and adhesion, even at high bacterial loadings up to 107 colony forming units per cm2.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...